Instrument Images
CR0225

3D PRINTER (3D CUBIC)

Make & Model: 3D CUBIC CUB 5.5
Location: CRF

Specification: Build Size: 550 x 550 x 550 mm Nozzle Diameter: 0.4 mm to 1.0 mm (optional) Printing Speed: Up to 200 mm/s Extruder Temperature: 30-300°C (upgradable) Bed Temperature: 30-150°C Accuracy: Z layer height of 80-600 microns (depends on nozzle) Connectivity: USB, SD card, Wi-Fi, U-disk Weight: 136 kg Material Compatibility: PLA+, ABS, PETG, HIPS, PVA, Carbon Fiber-Composite, PC, PP, TPU 90 Shore, Wood

 
Instrument Images
CR0226

3D PRINTER (MAKE 3D.IN PRATHAM 3.0)

Make & Model: 3D PRINTER (MAKE 3D.IN PRATHAM 3.0)
Location: CRF

Specification: PLA+ 1.75mm Build Size: 300 x 300 x 300 mm Nozzle Diameter: 0.4 mm (standard), with optional larger diameters Printing Speed: Up to 120 mm/s Extruder Temperature: Up to 280°C Bed Temperature: Up to 120°C Connectivity: USB, Wi-Fi, SD Card Software Compatibility: Supports various slicing software like Cura, Repetier, and Slicer Weight: Approximately 55 kg

 
Instrument Images
ID0084

7-Axis Faro Arm Scanner

Make & Model: Faro
Location: PDD Lab

Specification: Measurement Volume: Typically ranges from 1.2 meters to over 4 meters, depending on the model and configuration. Accuracy: Up to 25 microns (depending on the specific Faro Arm model and scanning technology). Scanning Speed: High-speed data capture, useful for both large and small objects. Connectivity: Integrated with FARO CAM2 Software for easy data collection, analysis, and CAD compatibility. Weight :Lightweight and portable, usually between 7 kg to 15 kg for easy deployment in different environments.

 
Instrument Images
CR0025

Abbe Refractometer

Make & Model: DR-M4/1550 Atago Co. Limited,Tokyo, Japan
Location: Glass Technology Laboratory

Specification: • Measurement range: Wavelength (RI) 450nm (1.5164-1.914), 589nm (1.4700- 1.8700), 680nm (1.4558-1.8557)

 
Instrument Images
CE0073

Accelerated Solvent Extractor

Make & Model: ASE 150, Thermo Fisher
Location: Environmental Engineering Laboratory

Specification: Elevated temperature and pressure reduce extraction times and solvent consumption. Temperature range: 40°C to 200°C. The temperature is used to accelerate solvent extraction by increasing the solvents ability to dissolve analytes from the sample matrix. Pressure: Up to 2000 psi (137 bar). The pressure is required to prevent solvent evaporation at elevated temperatures and to force solvents into the sample matrix. Cycle Time: The extraction cycle typically lasts 5 to 20 minutes, depending on sample type and the number of solvent washes required.

 